Brewing calculators
Calculate alcohol strength, plan water, and prepare your brew.
ABV calculator
Calculate ABV from Original Gravity (OG) and Final Gravity (FG). Choose the gravity scale shown by your hydrometer or brewing tool.
Brix, Plato, and Balling are very close for typical brewing readings, so this calculator uses the same approximate conversion for those scales; identical readings may give the same result. A post-fermentation refractometer Brix reading needs alcohol correction before using it as FG; enter a corrected reading here.
Correct a post-fermentation refractometer reading
Waiting for input
Still needed: OG, FG. Enter 0 where a value is zero; blanks are not treated as zero.
Dilution calculator
Find your new ABV after adding water, juice, or another alcohol-free liquid.
Your batch
Waiting for input
Still needed: current ABV, batch volume, volume added. Enter 0 where a value is zero; blanks are not treated as zero.
Target ABV calculator
Calculate how much liquid you must add to reach a specific ABV.
Your batch
Addition
Desired ABV
Waiting for input
Still needed: current ABV, batch volume, addition ABV, target ABV. Enter 0 where a value is zero; blanks are not treated as zero.
OG dilution calculator
Calculate your new OG after adding water or other non-sugar liquids.
Your batch
Waiting for input
Still needed: original OG, batch volume, water added. Enter 0 where a value is zero; blanks are not treated as zero.
Bottle-count calculator
Find how many bottles you can fill and how much volume will remain.
Waiting for input
Still needed: volume ready to bottle, bottle size. Enter 0 where a value is zero; blanks are not treated as zero.
All-grain water planner
Estimate strike, sparge, and pre-boil volumes from your target yield and equipment losses.
Saved equipment profiles
How do I measure my equipment values?
Boil-off rate: Measure the kettle volume before and after a timed boil, then divide the volume lost by the boil duration in hours. For example, losing 3 L in a one-hour boil is 3 L/hour. Repeat with your usual heat level and kettle setup.
Kettle / trub loss: After transferring wort the way you normally brew, measure the liquid left behind with the trub. Use the same method each time; this is separate from water evaporated during the boil.
Mash tun dead space: Add a measured amount of water to the tun, drain it as you do on brew day, and measure what remains below the outlet. Grain absorption is separate: estimate it over a brew by subtracting collected wort and tun dead space from the mash-and-sparge water used, then divide by the grain bill weight.
Mash ratio and grain bill: Use the grain amount from your recipe. Mash ratio is mash water per kilogram of grain; use your recipe or brewing method’s chosen ratio. It is a planning choice, not a fixed equipment measurement.
Your measurements will vary with boil vigor, grain crush, draining time, and technique. Treat one brew as a starting point and refine the values over a few consistent batches.
Enter measured values for your own equipment. This estimate assumes single-infusion all-grain brewing and does not account for decoction, top-up water, or changes in grain absorption.
Waiting for input
Still needed: target fermenter volume, boil time, boil-off rate, kettle loss, grain bill, grain absorption, mash ratio, tun dead space. Enter 0 where a value is zero; blanks are not treated as zero.
Water chemistry planner
Compare a source-water analysis with a starting ion profile and estimate additions for your brewing-water volume.
Saved water profiles
Saves the source-water analysis and target ions together. Sign in to save profiles to your account.
Where do I find these water values?
Start with your water supplier. Search for “water quality report” or “drinking water analysis” plus your city or supplier name. Some suppliers let you search by postcode or address. Look for calcium, magnesium, sodium, chloride, sulfate, and alkalinity.
For a private well, use a certified lab. Ask for a brewing water panel including those six values. If the report gives alkalinity as mg/L CaCO₃ rather than bicarbonate, multiply by 1.22 and enter the result as bicarbonate. For example, 50 mg/L as CaCO₃ is about 61 mg/L bicarbonate.
Reports often show a range or an annual average, and water can vary by location and season. Use a recent report for your supply, and contact the supplier if you are unsure which values apply to your tap. A basic bottled-water label may not list all six ions.
If you use reverse-osmosis or distilled water, enter zeros only when the product or your meter/test confirms it is effectively mineral-free; otherwise use its analysis. You can also leave this planner until you have a report and use the all-grain water planner without it.
Enter a water-report value for every source ion. The named profiles are editable starting points, not style rules. Salt additions target chloride, sulfate, magnesium, sodium, and bicarbonate; calcium is reported from those additions because these salts raise multiple ions. Salt assumptions are calcium chloride dihydrate, gypsum, Epsom salt heptahydrate, and baking soda. If your report gives alkalinity as CaCO₃, multiply it by 1.22 to estimate bicarbonate before entering it.
Waiting for input
Still needed: water volume, source Calcium, source Magnesium, source Sodium, source Chloride, source Sulfate, source Bicarbonate, target Calcium, target Magnesium, target Sodium, target Chloride, target Sulfate, target Bicarbonate. Enter 0 where a value is zero; blanks are not treated as zero.
Refractometer alcohol correction
Correct a post-fermentation refractometer reading using the original and current Brix values.
Use the Brix reading taken before fermentation and your refractometer’s current reading. A WCF of 1.04 is a common starting point, but it varies by refractometer and wort. Use the calibration below for a measured starting value.
Calibrate WCF with an unfermented wort sample
Take both readings from the same well-mixed wort sample before fermentation. Cool and correct the hydrometer reading for its calibration temperature. Recalibrate when switching refractometers or when wort composition changes.
Waiting for input
Still needed: calibration Brix, hydrometer OG. Enter 0 where a value is zero; blanks are not treated as zero.
Waiting for input
Still needed: original Brix, current Brix. Enter 0 where a value is zero; blanks are not treated as zero.
Using the brewing calculators
Results update automatically. “Waiting for input” lists missing fields; “Check your inputs” explains invalid values or impossible combinations. Enter an explicit zero where appropriate. Each calculated result includes its assumptions. Reset clears only that calculator and restores its default scale or mode; it does not delete saved profiles or change your unit preference. Refractometer reset restores WCF to 1.04; resetting the optional WCF calibration only clears its two sample readings.
The ABV calculator accepts specific gravity, Oechsle, Plato, Brix, or Balling for OG and FG, and converts those readings to specific gravity before estimating alcohol. For typical brewing readings Brix, Plato, and Balling are close enough that the calculator uses the same approximation for them, and ABV is displayed to two decimal places. For a post-fermentation refractometer reading, use the refractometer alcohol-correction calculator above before entering FG. Other gravity tools use specific-gravity values (for example, 1.050). Enter alcohol strength as a percentage and volume in the unit shown beside each field; the volume unit follows your saved preference when signed in or your local setting when signed out.
The gravity ABV estimate uses (OG − FG) × 131.25. Dilution tools assume volumes combine directly and alcohol is conserved; the OG dilution tool assumes the added liquid contains no fermentable sugar. Real mixtures can contract, and fermentation may not reach the assumed final gravity.
The bottle-count calculator divides the volume available to fill by the amount put in each bottle, then reports full bottles and any leftover volume. Enter the net volume ready to bottle and the planned fill volume per bottle; it does not estimate transfer loss or extra volume for spills or overfilling.
The all-grain water planner estimates mash, sparge, total, and pre-boil water from your target fermenter volume and measured equipment settings. Its saved equipment profiles store boil-off, kettle loss, grain absorption, mash ratio, and tun dead space. Measure these on your own setup and refine them over several brews; the estimate assumes a single-infusion mash and does not include top-up water or decoction.
The water chemistry planner uses a water report and a starting target ion profile to estimate mineral additions for the entered water volume. You can save named profiles containing both your source-water report and target ions for reuse. Check your supplier's latest report or use a certified lab for well water. Salt combinations affect multiple ions, so review the predicted values rather than expecting every target to match exactly. The acid estimate only approximates alkalinity neutralization; it does not predict mash pH. Treat additions as a starting point, follow product instructions, and verify with measurements.